public class Counter extends Object implements CounterBase, Sendable, AutoCloseable
Class for counting the number of ticks on a digital input channel.
This is a general purpose class for counting repetitive events. It can return the number of counts, the period of the most recent cycle, and detect when the signal being counted has stopped by supplying a maximum cycle time.
All counters will immediately start counting - reset() them if you need them to be zeroed before use.
-
Nested Class Summary
Nested Classes Modifier and Type Class Description static class
Counter.Mode
Mode determines how and what the counter counts.Nested classes/interfaces inherited from interface edu.wpi.first.wpilibj.CounterBase
CounterBase.EncodingType
-
Field Summary
Fields Modifier and Type Field Description protected DigitalSource
m_downSource
protected DigitalSource
m_upSource
-
Constructor Summary
Constructors Constructor Description Counter()
Create an instance of a counter where no sources are selected.Counter(int channel)
Create an instance of a Counter object.Counter(AnalogTrigger trigger)
Create an instance of a Counter object.Counter(Counter.Mode mode)
Create an instance of a counter with the given mode.Counter(CounterBase.EncodingType encodingType, DigitalSource upSource, DigitalSource downSource, boolean inverted)
Create an instance of a Counter object.Counter(DigitalSource source)
Create an instance of a counter from a Digital Input. -
Method Summary
Modifier and Type Method Description void
clearDownSource()
Disable the down counting source to the counter.void
clearUpSource()
Disable the up counting source to the counter.void
close()
int
get()
Read the current counter value.boolean
getDirection()
The last direction the counter value changed.double
getDistance()
Read the current scaled counter value.int
getFPGAIndex()
The counter's FPGA index.double
getPeriod()
Get the Period of the most recent count.double
getRate()
Get the current rate of the Counter.int
getSamplesToAverage()
Get the Samples to Average which specifies the number of samples of the timer to average when calculating the period.boolean
getStopped()
Determine if the clock is stopped.void
initSendable(SendableBuilder builder)
Initializes thisSendable
object.void
reset()
Reset the Counter to zero.void
setDistancePerPulse(double distancePerPulse)
Set the distance per pulse for this counter.void
setDownSource(int channel)
Set the down counting source to be a digital input channel.void
setDownSource(AnalogTrigger analogTrigger, AnalogTriggerOutput.AnalogTriggerType triggerType)
Set the down counting source to be an analog trigger.void
setDownSource(DigitalSource source)
Set the source object that causes the counter to count down.void
setDownSourceEdge(boolean risingEdge, boolean fallingEdge)
Set the edge sensitivity on a down counting source.void
setExternalDirectionMode()
Set external direction mode on this counter.void
setMaxPeriod(double maxPeriod)
Set the maximum period where the device is still considered "moving".void
setPulseLengthMode(double threshold)
Configure the counter to count in up or down based on the length of the input pulse.void
setReverseDirection(boolean reverseDirection)
Set the Counter to return reversed sensing on the direction.void
setSamplesToAverage(int samplesToAverage)
Set the Samples to Average which specifies the number of samples of the timer to average when calculating the period.void
setSemiPeriodMode(boolean highSemiPeriod)
Set Semi-period mode on this counter.void
setUpdateWhenEmpty(boolean enabled)
Select whether you want to continue updating the event timer output when there are no samples captured.void
setUpDownCounterMode()
Set standard up / down counting mode on this counter.void
setUpSource(int channel)
Set the upsource for the counter as a digital input channel.void
setUpSource(AnalogTrigger analogTrigger, AnalogTriggerOutput.AnalogTriggerType triggerType)
Set the up counting source to be an analog trigger.void
setUpSource(DigitalSource source)
Set the source object that causes the counter to count up.void
setUpSourceEdge(boolean risingEdge, boolean fallingEdge)
Set the edge sensitivity on an up counting source.
-
Field Details
-
Constructor Details
-
Counter
Create an instance of a counter with the given mode.- Parameters:
mode
- The counter mode.
-
Counter
public Counter()Create an instance of a counter where no sources are selected. Then they all must be selected by calling functions to specify the upsource and the downsource independently.The counter will start counting immediately.
-
Counter
Create an instance of a counter from a Digital Input. This is used if an existing digital input is to be shared by multiple other objects such as encoders or if the Digital Source is not a DIO channel (such as an Analog Trigger)The counter will start counting immediately.
- Parameters:
source
- the digital source to count
-
Counter
Create an instance of a Counter object. Create an up-Counter instance given a channel.The counter will start counting immediately.
- Parameters:
channel
- the DIO channel to use as the up source. 0-9 are on-board, 10-25 are on the MXP
-
Counter
public Counter(CounterBase.EncodingType encodingType, DigitalSource upSource, DigitalSource downSource, boolean inverted)Create an instance of a Counter object. Create an instance of a simple up-Counter given an analog trigger. Use the trigger state output from the analog trigger.The counter will start counting immediately.
- Parameters:
encodingType
- which edges to countupSource
- first source to countdownSource
- second source for directioninverted
- true to invert the count
-
Counter
Create an instance of a Counter object. Create an instance of a simple up-Counter given an analog trigger. Use the trigger state output from the analog trigger.The counter will start counting immediately.
- Parameters:
trigger
- the analog trigger to count
-
-
Method Details
-
close
- Specified by:
close
in interfaceAutoCloseable
-
getFPGAIndex
The counter's FPGA index.- Returns:
- the Counter's FPGA index
-
setUpSource
Set the upsource for the counter as a digital input channel.- Parameters:
channel
- the DIO channel to count 0-9 are on-board, 10-25 are on the MXP
-
setUpSource
Set the source object that causes the counter to count up. Set the up counting DigitalSource.- Parameters:
source
- the digital source to count
-
setUpSource
public void setUpSource(AnalogTrigger analogTrigger, AnalogTriggerOutput.AnalogTriggerType triggerType)Set the up counting source to be an analog trigger.- Parameters:
analogTrigger
- The analog trigger object that is used for the Up SourcetriggerType
- The analog trigger output that will trigger the counter.
-
setUpSourceEdge
Set the edge sensitivity on an up counting source. Set the up source to either detect rising edges or falling edges.- Parameters:
risingEdge
- true to count rising edgefallingEdge
- true to count falling edge
-
clearUpSource
Disable the up counting source to the counter. -
setDownSource
Set the down counting source to be a digital input channel.- Parameters:
channel
- the DIO channel to count 0-9 are on-board, 10-25 are on the MXP
-
setDownSource
Set the source object that causes the counter to count down. Set the down counting DigitalSource.- Parameters:
source
- the digital source to count
-
setDownSource
public void setDownSource(AnalogTrigger analogTrigger, AnalogTriggerOutput.AnalogTriggerType triggerType)Set the down counting source to be an analog trigger.- Parameters:
analogTrigger
- The analog trigger object that is used for the Down SourcetriggerType
- The analog trigger output that will trigger the counter.
-
setDownSourceEdge
Set the edge sensitivity on a down counting source. Set the down source to either detect rising edges or falling edges.- Parameters:
risingEdge
- true to count the rising edgefallingEdge
- true to count the falling edge
-
clearDownSource
Disable the down counting source to the counter. -
setUpDownCounterMode
Set standard up / down counting mode on this counter. Up and down counts are sourced independently from two inputs. -
setExternalDirectionMode
Set external direction mode on this counter. Counts are sourced on the Up counter input. The Down counter input represents the direction to count. -
setSemiPeriodMode
Set Semi-period mode on this counter. Counts up on both rising and falling edges.- Parameters:
highSemiPeriod
- true to count up on both rising and falling
-
setPulseLengthMode
Configure the counter to count in up or down based on the length of the input pulse. This mode is most useful for direction sensitive gear tooth sensors.- Parameters:
threshold
- The pulse length beyond which the counter counts the opposite direction. Units are seconds.
-
get
Read the current counter value. Read the value at this instant. It may still be running, so it reflects the current value. Next time it is read, it might have a different value.- Specified by:
get
in interfaceCounterBase
- Returns:
- the count
-
getDistance
Read the current scaled counter value. Read the value at this instant, scaled by the distance per pulse (defaults to 1).- Returns:
- The distance since the last reset
-
reset
Reset the Counter to zero. Set the counter value to zero. This doesn't effect the running state of the counter, just sets the current value to zero.- Specified by:
reset
in interfaceCounterBase
-
setMaxPeriod
Set the maximum period where the device is still considered "moving". Sets the maximum period where the device is considered moving. This value is used to determine the "stopped" state of the counter using the GetStopped method.- Specified by:
setMaxPeriod
in interfaceCounterBase
- Parameters:
maxPeriod
- The maximum period where the counted device is considered moving in seconds.
-
setUpdateWhenEmpty
Select whether you want to continue updating the event timer output when there are no samples captured. The output of the event timer has a buffer of periods that are averaged and posted to a register on the FPGA. When the timer detects that the event source has stopped (based on the MaxPeriod) the buffer of samples to be averaged is emptied. If you enable the update when empty, you will be notified of the stopped source and the event time will report 0 samples. If you disable update when empty, the most recent average will remain on the output until a new sample is acquired. You will never see 0 samples output (except when there have been no events since an FPGA reset) and you will likely not see the stopped bit become true (since it is updated at the end of an average and there are no samples to average).- Parameters:
enabled
- true to continue updating
-
getStopped
Determine if the clock is stopped. Determine if the clocked input is stopped based on the MaxPeriod value set using the SetMaxPeriod method. If the clock exceeds the MaxPeriod, then the device (and counter) are assumed to be stopped and it returns true.- Specified by:
getStopped
in interfaceCounterBase
- Returns:
- true if the most recent counter period exceeds the MaxPeriod value set by SetMaxPeriod.
-
getDirection
The last direction the counter value changed.- Specified by:
getDirection
in interfaceCounterBase
- Returns:
- The last direction the counter value changed.
-
setReverseDirection
Set the Counter to return reversed sensing on the direction. This allows counters to change the direction they are counting in the case of 1X and 2X quadrature encoding only. Any other counter mode isn't supported.- Parameters:
reverseDirection
- true if the value counted should be negated.
-
getPeriod
Get the Period of the most recent count. Returns the time interval of the most recent count. This can be used for velocity calculations to determine shaft speed.- Specified by:
getPeriod
in interfaceCounterBase
- Returns:
- The period of the last two pulses in units of seconds.
-
getRate
Get the current rate of the Counter. Read the current rate of the counter accounting for the distance per pulse value. The default value for distance per pulse (1) yields units of pulses per second.- Returns:
- The rate in units/sec
-
setSamplesToAverage
Set the Samples to Average which specifies the number of samples of the timer to average when calculating the period. Perform averaging to account for mechanical imperfections or as oversampling to increase resolution.- Parameters:
samplesToAverage
- The number of samples to average from 1 to 127.
-
getSamplesToAverage
Get the Samples to Average which specifies the number of samples of the timer to average when calculating the period. Perform averaging to account for mechanical imperfections or as oversampling to increase resolution.- Returns:
- SamplesToAverage The number of samples being averaged (from 1 to 127)
-
setDistancePerPulse
Set the distance per pulse for this counter. This sets the multiplier used to determine the distance driven based on the count value from the encoder. Set this value based on the Pulses per Revolution and factor in any gearing reductions. This distance can be in any units you like, linear or angular.- Parameters:
distancePerPulse
- The scale factor that will be used to convert pulses to useful units.
-
initSendable
Description copied from interface:Sendable
Initializes thisSendable
object.- Specified by:
initSendable
in interfaceSendable
- Parameters:
builder
- sendable builder
-